14. Service call message
14.3.23
0500: Heating Roller warm-up failure
14.3.24
0501: Fusing Pressure Roller warm-up failure
14.3.25
0510: Abnormally low Heating Roller temperature
14.3.26
0511: Abnormally low Fusing Pressure Roller temperature
14.3.27
0520: Abnormally high Heating Roller temperature
14.3.28
0521: Abnormally high Fusing Pressure Roller temperature
Fusing Unit
Step
Check the Fusing Unit for correct installa-
1
tion (whether it is secured in position).
Check the Fusing Unit, PWB-M and PU1
2
for proper connection and correct or
change as necessary.
3
Change Fusing Unit
4
Change PWB-M
5
Change PU1
14.3.29
0900: Tray 4 Elevator failure
14.3.30
0910: Tray 3 Elevator failure
14.3.31
0950: Tray 5 Elevator failure
Lift-Up Sensor (PC7)
Lift-Up Motor (M3)
Step
Check the M3 connector for proper connec-
1
tion and correct as necessary.
Check the connector of M3 for proper drive
2
coupling and correct as necessary.
3
PC7 I/O check, Sensor check
4
M3 operation check
5
Change PWB-Z
198
Relevant Electrical Parts
Action
Relevant Electrical Parts
Action
Field Service Ver. 1.0 May 2006
DC Power Supply (PU1)
Mechanical Control Board (PWB-M)
WIRING DIAGRAM
Control Signal
—
—
—
—
—
Control Board (PWB-Z)
WIRING DIAGRAM
Control Signal
—
—
PWB-Z PJ6Z PC-3 (ON)
PWB-Z PJ4Z PC-4 to 5
—
Location (Electri-
cal Component)
—
—
—
—
—
Location (Electri-
cal Component)
—
—
V-21 to 22
Q-24
—