Silent-Time; Databits - Digisol DG-FS4526 Management Manual

Mustang 4000 switch series
Table of Contents

Advertisement

Command Usage
• When the logon attempt threshold is reached, the system interface becomes
silent for a specified amount of time before allowing the next logon attempt.
(Use the silent-time command to set this interval.) When this threshold is
reached for Telnet, the Telnet logon interface shuts down.
• This command applies to both the local console and Telnet connections.
Example
To set the password threshold to five attempts, enter this command:
Console(config-line)#password-thresh 5
Console(config-line)#
Related Commands

silent-time (4-15)

timeout login response (4-13)
silent-time
This command sets the amount of time the management console is inaccessible
after the number of unsuccessful logon attempts exceeds the threshold set by the
password-thresh command. Use the no form to remove the silent time value.
Syntax
silent-time [seconds]
no silent-time
seconds - The number of seconds to disable console response.
(Range: 0-65535; 0: no silent-time)
Default Setting
The default value is no silent-time.
Command Mode
Line Configuration
Example
To set the silent time to 60 seconds, enter this command:
Console(config-line)#silent-time 60
Console(config-line)#
Related Commands
password-thresh (4-14)

databits

This command sets the number of data bits per character that are interpreted and
generated by the console port. Use the no form to restore the default value.
www.digisol.com
DG-FS4526 User Manual
4
4-15

Hide quick links: