SELF-DIAGNOSIS
FUNCTION
K2
CODE No.62
3-4 SHIFT
SOLENOID
VALVE
iTEP
INSPECTION
ACTION
1
Are there any poor connections
in 3-4 shift sole-
Yes
Repair connector
and/or wiring
noid valve circuit?
No
Go to next step
2
Does EC-AT Tester 3-4 solenoid
valve lamp il-
Yes
3-4 shift solenoid
valve OK
luminate
as shown
in solenoid
valve operation
Cancel memory of code number
table? (Refer to page K2-117)
No
Go to next step
3
Is there continuity
of transistor
in EC-AT control
Yes
Go to next step
unit?
Terminal
Continuity
No
1
Replace
EC-AT control
unit and continue
with next step
21 and IJ or 2P
Yes
4
Is resistance
of 3-4 shift solenoid
valve OK?
Yes
Go to Step 6
Terminal
Resistance
D and ground
13-2752
No
Go to next step
5
Are there any poor connections
at connector
in
Yes
Repair connector
transaxle?
No
Go to next step
6
Is there continuity
between
terminal
of EC-AT
Yes
Replace
EC-AT control
unit
control
unit connector
and ground?
Terminal
21 and ground
Continuity
Yes
No
Check for open circuit in wiring
03UOK2-Ot
CODE No.63
LOCKUP
SOLENOID
VALVE
STEP
INSPECTION
ACTION
1
Are there any poor connections
in lockup sole-
Yes
Repair connector
and/or wiring
noid valve circuit?
No
Go to next step
2
Does EC-AT Tester lockup
solenoid
valve lamp
Yes
Lockup
solenoid
valve OK
illuminate
as shown
in solenoid
valve operation
Cancel memory of code number
table? (Refer to page K2-117)
No
Go to next step
3
Is there continuity
of transistor
in EC-AT control
Yes
Go to next step
I
I unit?
I
I
I
Terminal
Continuity
No
1
Replace
EC-AT control
unit then continue
with next step
2K and IJ or 2P
Yes
4
Is resistance
of lockup solenoid
valve OK?
Yes
Go to Step 6
I I
Terminal
Resistance
E and ground
13-27Q
-
No
Go to next step
5
Are there any poor connections
at connector
in
Yes
Repair connector
transaxle?
No
Go to next step
6
Is there continuity
between
terminal
of EC-AT
Yes
Replace
EC-AT control unit
control unit connector
and ground?
I II
Terminal
Continuity
No
Check for open circuit in wiring
2K and ground
Yes