1.2

Technical Data

1.2.1

Mechanical Data

For dimensions, type of enclosure and weight see the appended
Dimensional Drawing 102--890.HP005 for Autopilot 102--890.NG001 or
Dimensional Drawing 102--890.HP015 for Autopilot 102--890.NG002.
1.2.2

Electrical Data

Supply voltage (plug B12)
Power consumption
Ambient temperature (operation)
Ambient temperature (storage)
Outputs (Status):
-- Status and alarm contacts
(plugs B3, B4, B5 and B6)
Inputs (Status):
Status (plugs B10 and B11)
Outputs/Inputs:
Serial in/out (plugs B8 and B9)
CAN bus (plugs B21 and B22)
LAN
Signal Inputs:
Gyro Compass, Satellite Compass
Magnetic Compass/Fluxgate
Speed Log
Position Receiver
ECDIS (for Track Control)
*NMEA according to IEC 61162--1, --2
1.2.3

Cable length and diameters

CAN bus
Status lines
Power lines
Edition: September 2014
OPERATION
NautoPilot 5000 Series
24V DC (18 to 36V DC)
Approx. 25 W
--25 C to +55 C
--40 C to +70 C
Output load 30V DC, Imax. 1A
24V DC, Imax. 5mA
RS422 (NMEA)
according to RAN CAN bus specification
(ETHERNET)
Course Bus or NMEA*
Course Bus or NMEA*
Course Bus or NMEA*
NMEA*
according to IEC 62065,
APB NMEA*
4x2.0x0.75 twisted/screened, max. 400 meters
2
1mm
1.5mm
7
2
AUTOPILOT
4002.DOC010102

Hide quick links: