Raytheon NautoPilot NP 5100 Operator's Manual page 172

Nautopilot operator unit 102--890 ng001/ng002
Table of Contents

Advertisement

TC Interr
No Set Course
----------------------------------------------
Trck.Ctrl.Interr
TC Interr
No Position
----------------------------------------------
Trck.Ctrl.Interr
Track Course--Heading
Difference
----------------------------------------------
TrckCrs--HDG. Diff
Track End 000min
----------------------------------------------
Track End 000min
Track End Passed
Change Steering Mode
----------------------------------------------
Track End Passed
Track external error
----------------------------------------------
Trck.ext. ERR
TC Interr Change Angle
too big
----------------------------------------------
Trck.Ctrl.Interr
4002.DOC010102
OPERATION
NautoPilot 5000 Series
Message
ECDIS fails.
Track Control interrup-
tion due to lack of posi-
tion data.
A difference between ac-
tual heading and set
course has been found.
Drift is too strong.
000 minutes left to track end.
During track control the
track end is passed.
This alert comes up ev-
ery 7 seconds until hav-
ing changed over to
heading control or
manual mode.
Faulty track data.
Data is generated by an
external device.
During track control, the
next track change angle
is too big.
Possible cause
160
Remedy
Check ECDIS.
Check position sensor.
-- Check RAD/RoT
adjustments
(see section 2.3.6.3).
-- Check Rudder limit
adjustments
(see section 2.3.6.4).
-- Check limit settings
for Course trim
(see section 2.3.6.4).
-- Check the control
loop for the Course
Trim
(see section 2.3.6.4).
Switch over to
Track Control or
Heading Control.
Change over to heading
control or manual mode.
Check external device.
Check route.
For explanation of the
error,
see section 1.4.5.1.7.4.