Figure 52/5
Figure 52/6
Figure 52/7
2.3.6.5

Parameter setting

Figure 53: Parameter setting ("Page" function)
Changes of these parameters will be adopted to the current mode (Heading Control,
Course Control or Track Control). Using the NP5500 changes will only be adopted to
mode Heading Control mode.
4002.DOC010102
OPERATION
NautoPilot 5000 Series
Track Limit Autopilot; this value activates an alert if the adjusted
value exceeds a track limit (stb or pt) -- active in Course Control
mode only.
Value range: 10m to 2000m, (in increments of 1m).
OFF Position Limit; this value generates an alarm if the OFF
position (according to section 2.3.5.5) is exceeded.
Value range: 0m to 9999m, (in increments of 1m) (if configured).
Only for NP 5400 and NP 5500.
Adjustment of the acceleration limit (see also section 2.3.5.4.1).
Value range: 0.000 to 9.999 m/s
88
Function
2
, increment of 0.001m/s
1
2
3
4
5
2
Edition: September 2014