Figure 54: Example Of A Request To Press "Set" After A Parameter Has Been Changed - Raytheon NautoPilot NP 5100 Operator's Manual

Nautopilot operator unit 102--890 ng001/ng002
Table of Contents

Advertisement

Table 14
Figure 53/1
Figure 53/2
Figure 53/3
Figure 53/4
Figure 53/5

Figure 54: Example of a request to press "SET" after a parameter has been changed

Edition: September 2014
OPERATION
NautoPilot 5000 Series
Meanings of parameter settings ("Page function")
Softkey for changing/entering the yawing parameter (see also
section 1.3.1). Value range: 1 to 6 (in increments of 1).
Use the "+" and "--" softkeys to make a change.
Changes must be acknowledged with "SET" (a small icon is
displayed after a change has been made, see Figure 54).
Softkey for changing/entering the rudder parameter (see also
section 1.3.2). Value range: 1 to 9 (in increments of 1).
Use the "+" and "--" softkeys to make a change.
Changes must be acknowledged with "SET" (a small icon is
displayed after a change has been made, see Figure 54).
Softkey for changing/entering the counter rudder parameter
(see also section 1.3.3). Value range: 0 to 9
(in increments of 1).
Use the "+" and "--" softkeys to make a change.
Changes must be acknowledged with "SET" (a small icon is
displayed after a change has been made, see Figure 54).
In adaptive mode only. Softkey for changing/entering the ship
load condition parameter (see also section 1.3.4). Value range:
10% to 100% (in increments of 10%).
Use the "+" and "--" softkeys to make a change.
Changes must be acknowledged with "SET" (a small icon is
displayed after a change has been made, see Figure 54).
Softkey for changing/entering the Track Econ parameter to in-
fluence rudder activity (see section 1.3.8).