Connecting to the CallPilot 100/150

To connect to the CallPilot 100/150
and a connection to the network that the CallPilot 100/150 is on.
The default IP address for CallPilot 100/150 is 192.168.110.10.
If the default IP address is compatible with your network, you can connect the LAN cable to the
Ethernet port on the CallPilot 100/150 and proceed to
35.
If the default IP address is not compatible, you must change the IP address before you connect the
CallPilot 100/150 to the network. You can change the IP address using a serial cable or an Ethernet
crossover cable (direct PC connection).
Note: If you are unsure if the default IP address is compatible, contact your network
administrator.

Changing the IP address using a serial cable

If you are going to change the IP address using a serial cable, you need a:
serial cable
VT100-compatible terminal or a computer that has a VT100 compatible terminal emulation
program such as HyperTerminal
Note: The serial port is intended for temporary connections only. After you have finished
changing the IP address, remove the serial cable and close the CallPilot 100/150 door.
Failure to remove the serial cable may result in a non-compliant EMC configuration.
Note: A serial cable is available as a separately available part. For information about
obtaining a serial cable, contact your Nortel Networks supplier.
CallPilot 100/150 serial port
The following table shows the pin out for the CallPilot 100/150 serial port.

Table 7 CallPilot 100/150 serial port pinout

1 2 3 4 5
6 7 8 9
Chapter 5 Initializing the CallPilot 100/150
CallPilot 100, you need the IP address of the CallPilot 100/150
/
Pin
Signal
1
No connection
2
Serial data in (RX)
3
Serial data out (TX)
4
No connection
5
Ground
CallPilot 100/150 Installation and Maintenance Guide
"Running the Quick Install Wizard" on page
Pin
Signal
6
No connection
7
No connection
8
No connection
9
No connection