Control Setting Of Component - Omron NB Series Operation Manual

Nb-series programmable terminals
Hide thumbs Also See for NB Series:
Table of Contents

Advertisement

3 Functions of NB-Designer

3-5-11 Control Setting of Component

Option
Touching
Always
Enabled
Valid
Setting
Always
Invalid
Conditional
Enabling
Show
Elements
Invalid Tag
Security
Min Press
Setting
Time
Operator
Confirm
Record
Operations
Min Time
Inteval
Notifications
Trigger
Macro
Trigger
Register
3-74

Control Setting of Component

Descriptions
Checking this option means the state value can be effectively written into the controller by
triggering the effective area for the current component.
Checking this option means the state value can't be effectively written into the controller by
triggering the effective touching area for the current component.
Security Level: Checking this option means only when the security level of the operator is
higher than the minimum security level already set, the current component can be touched,
and the state value can be written into the controller.
Permission Control: Checking this option means the operator needs to have the set authority to
touch the current component and write the state value into the controller.
Register Control: Checking this option means only when the state of the specified bit register or
word register meets the set conditions, the current component can be touched, and the state
value can be written into the controller.
Password
Checking this option means the Password Input Window Frame 9 (Login
Window Pops
window) will pop up automatically for the user to input the password for
Up
convenient login when the security level or the permission of the current user
Automatically
doesn't meet the requirement of the set level or authority.
Checking this option means display invalid tag for the component will be displayed when the
component is in invalid touching status. This function can only be checked only when [Always
Invalid] or [Conditional Enabling] is checked; and touching invalid color can be set in [HMI
Attribute]-[HMI Extended Attributes].
The state value can be effectively written into the controller only when the current component is
pressed consecutively for this set time. The minimum unit is 100 ms. When this option is 0, it
means the minimum press time doesn't need to be set.
Checking this option means the Confirm Action window will pop up automatically when the
current component is touched, and the state value can be written into the controller when
"YES" is clicked, while the operation will be cancelled automatically when the user have clicked
"Cancel" or haven't confirmed "YES" after the set "wait[s]" is exceeded.
Checking this option means the operation event will be recorded, and displayed through the
operation log element and saved into the external memory as the file in CSV format.
Refers to the minimum interval between 2 operations for the same component or different
components. The minimum unit is second. When this option is 0, it means the minimum interval
doesn't needs to be set.
When this button is triggered, the specified Macro codes will be triggered and executed before
the current operation is performed successfully.
Word
Written Notice
After Written
Notice
Bit
Written Notice
After Written
Notice
NB-series Programmable Terminals NB-Designer Operation Manual(V106)
Writes the write-value into the specified word register
before the current operation is performed successfully.
Writes the write-value into the specified word register after
the current operation is performed successfully.
Writes ON/OFF signal into the specified bit register before
the current operation is performed successfully.
Writes ON/OFF signal into the specified bit register after
the current operation is performed successfully.