Omron NB Series Operation Manual page 353

Nb-series programmable terminals
Hide thumbs Also See for NB Series:
Table of Contents

Advertisement

3 Functions of NB-Designer
Addresses
9044
Save communication settings to system
9045
Restart HMI
9046
Low security level
9050
Return to factory settings
9051
Control the execution of touch operation
when the backlight is off.
9052
Disenable Write Back function of [PLC
Control] / [Change window]
9053
Touch mark
9055
Operation at disconnection: PLC
9056
Operation at disconnection: touch
control
9060
Keyboard control bit: Popup of keyboard
controlled by the component on the left
of window
9061
Keyboard control bit: Popup of keyboard
controlled by the component on the left
of window
9062
Keyboard control bit: Popup of keyboard
controlled by the component on the
upper left of window
9063
Keyboard control bit: Popup of keyboard
controlled by the component on the
lower left of window
3-312
Descriptions
NB-series Programmable Terminals NB-Designer Operation Manual(V106)
Comments
Set it to ON to perform this function and write the
communication parameters of LW10000 area back to
EE for saving. Only writing the communication
parameters back to EE can ensure the settings are
valid at the next startup.
Set it to ON to perform this function (write).
This bit will be turned ON when we enter the higher
security level from the lower security level (read).
Set it to ON to perform this function and the system will
save the default global settings in the downloaded data
file to LW10000 system parameter area, and will
automatically clear this bit to zero after successful
download.
Setting it to ON can disenable the touch operation of
HMI when the backlight is closed (read/write).
Set it to ON to disenable the Write Back function of
PLC. And it is only applicable to Write Back function of
[PLC Control] / [Change window]. The Write Back
function is not disenabled when the value of LB9052 is
OFF. In this case, if you want to switch from Basic
window 10 to Basic window 12 by using [PLC Control] /
[Change window] (Read address: D20), the switching
can be controlled only when the value of D20 is 12.
And the PLC will write 12 back to the word address
D21 automatically after the window is switched to the
Basic window 12. If the Write Back function is
disenabled, 12 will not be written back to D21
(read/write).
It will turn ON when the Trigger Touch component is
pressed while OFF when the Trigger Touch component
is released (read).
When PLC is disconnected from NB Unit, the relevant
operation will be performed according to the contents
of LB9055. OFF: All the commands written to PLC are
invalid. ON: Operation is normal.
When PLC is disconnected from NB Unit, the relevant
operation will be performed according to the contents
of LB9056. OFF: Enable the touch operation. ON:
Disenable the touch operation.
When the user activate the Number Input or Text Input
components, the NB Unit turns ON this bit, and the
Direct Window including the keyboard will pop up. This
bit will turn OFF when the input is successful or the
[Esc] button is pressed. The user can use this bit to
control the popup of the keyboard. The keyboard
window will automatically turn OFF when the input is
successful or is cancelled. (Refer to the descriptions
described in the later part of this table for the keyboard
control bit.) (read)
Refer to the descriptions described in the later part of
this table for the usage of LB9060 to LB9069, LB9080
and LB9081 (read).
(Read).
(Read).