"Back Space" and "Clear" functions of Function Key is prior to the input Pinyin characters, i.e. when
the Pinyin characters are input currently, the object operated by the "Back Space" and "Clear"
function is the Pinyin characters instead of the other characters in the text input area.
Note When the font size is 8, 24, 48, 72 or 96, the Pinyin input method is invalid.
9
LSB Type
LSB type is applicable to the Multiple State Setting component, Multiple State Display
component, and Multiple State Neon Lamp component. It uses the least significant bit location
to control the text display, which is helpful to the control of the neon lamp by using the input bit
state.
10
Mask Station No.
The device not involved in the communication can be masked with this function and "PLC No
Response" will not be displayed any more. And the other devices with normal communication
can be used normally.
11
Trend Curve, XY Plot and Oscillograph
Trend Curve/XY Plot/Oscillograph components have extended attributes, as shown below:
(a) Border, Grid and Background Color etc.
(b) Connect Type of sampling point.
(c) Sampling cycle can use the variable.
(d) The style of XY Plot are scatter plot and shaded plot.
(e) Sampling points can use the variable.
(f) The Trend Curve can be saved to the HMI and external devices simultaneously.
When the variable is used in the sampling cycle and sampling points, the variable will be given
the priority to be used. And if the variable value can't be obtained for the failure of the
communication connection, the preset value will be used.
For example, when the Trend Curve/XY Plot/Oscillograph use the extended attributes.