3 Functions of NB-Designer
Recipe Card Address
RW100
RW130
RW150
RW170
• • • • • •
• • • • • •
RW4090
RW4110
The size of the reserved memory is 200×20+30=4030 words. For the user, this part of memory area is
read-only, any write-operation will cause unexpected result. The user can set the starting address of
the data freely, but should pay attention to the following points:
(1) The designed memory area can't conflict with the address of project component.
(2) The memory area can't exceed RW60000 because the addresses following RW60000 are pre-
reserved by the system.

3-10-8 COM1/COM2 Setting

There are [COM1 Setting] and [COM2 Setting] here because NB Unit has 2 serial ports. You can make
the connection to 2 PLCs through these two serial ports. The settings of these two serial ports are
completely same, so we only describe one serial port.
Type: Selects the communication method between the HMI and PLC from RS-232, RS-422 and RS-
485.
Baud Rate, Data Bit, Parity Check and Stop Bit: Selects the communication parameters matching
the PLC.
3-308