6 Descriptions of New Functions Added into NB
6-3

Component Improvement

6-3-1

Function Key

Save Screenshot to The Extended Memory
When the state of the specified register turns ON from OFF, the content of the current screen will be
stored into the external memory in the form of "bmp picture", thus making the operation screen of HMI
viewed conveniently.
Note 1 "Save Screenshot to The Extended Memory" is only applicable to the HMI with USB HOST.
2 Function of "Save Screenshot to The Extended Memory" supports the offline simulation, indirect online
simulation and direct online simulation. All the screenshot pictures got by this simulation method are
stored in the "\disk\usb1\scr" file under the installation directory of NB-Designer software.
To save the screenshot to the specified external memory, it needs to make settings in the [HMI] tab in
[HMI Attribute] dialog box.
The ".rmp" pictures stored in the external storage device is named in storage time form (i.e. "yyyy-mm-
dd, hour: minute; second; millisecond" form) by default, such as "2010-09-01, 10:12:50:203.bmp". But
the picture name can be customized by the user through the system register LW9470 to control the
prefix title of the picture file. For example: if the text contents of 16 words from LW9470 to LW9485 are
"Version No. -Num.20100001-", then the "bmp" file will be stored with the name of "Version No. -
Num.20100001-2010-09-01, 10:15:28:421.bmp".
Note After the "Save Screenshot to The Extended Memory" operation is performed for about 1 minute, the exter-
nal storage device can be removed to ensure the successful storage of the screenshot.
6-14
-TW01B
NB-Series Programmable Terminals NB-Designer Operation Manual(V106)