3 Functions of NB-Designer
3-6-9

Animation

The Animation component is used to put the component into the position with the specified
track in the HMI, and this position is determined by the preset path and the data of PLC. The status and
absolute position of the component in the HMI is determined by the data in the 2 consecutive PLC
registers. Generally speaking, the 1
position in the preset path respectively. When the values in the position register of PLC change, the
vector graphics or bitmap will jump to the next position in the preset path.
Process of adding one Animation component
1
Press the Animation component icon.
2
Set the path and moving point for the component in the HMI, left click the mouse one by one on
each moving node, and right-click the mouse after the setup of path and moving nodes to
complete the setup.
3
Double-click the Animation component and add the content in [Basic Attributes] tab after the
[Animation Component Attributes] dialog box pops up.
Read Address: Refers to the word address controlling the state and tag of the Moving
3-112
register and the 2
st
Component in PLC, and [Read Address + 1] refers to the word address
controlling the poison of the Animation component. The data in the register
will be converted into BIN or BCD format (Refer to the Multiple State Display
component.). Here, [Word Length] is limited to 2.