Omron NB Series Operation Manual page 307

Nb-series programmable terminals
Hide thumbs Also See for NB Series:
Table of Contents

Advertisement

3 Functions of NB-Designer
That's to say, the program will read 2-word data beginning from LW200 and then write it into 2
words beginning from LW202. In order to testify this code segment will be executed
successfully, you should place 4 Number Input components and 1 Function Key to execute the
Macro in the HMI Edit window, as shown below:
Macro
Perform the offline simulation:
Make LW200=1 and LW201=2, then click the [Macro] button, and you will find LW202=1 and
LW203=2. The Macro is executed normally.
Macro
Macro
4
[Import variable/Export variable] functions are provided for user to copy Macro variables and
Macrocode.
Right-click "Parameters [directaccesslocaladdr.c]", you will see the [Import variable] option; and
you will see the [Export variable] option is also activated after you have created a new variable.
3-266