Field Service Ver1.0 Jun.2005
4.2

DF hinge pressure adjustment

In this adjustment, the spring pressure when the DF is opened and closed is adjusted.
A. Procedure
[2]
1. Close the DF.
2. Loosen the nuts [1], one each provided on both
sides.
3. Open the DF.
4. Rotate the adjusting screw [2] to adjust the spring
pressure of the hinge.
Tighten (clockwise): Spring pressure decreased.
Loosen
increased.
5. Close the DF.
6. Tighten securely the nuts [1], one each provided
[1]
on both sides.
15saf3c002na
4. MECHANICAL ADJUSTMENT
(counterclockwise):
Spring
pressure
35