Cleaning The Read Section Sensor/Mirror For The Sensor; Maintenance Procedure Of The Paper Exit Section; Cleaning The Mirror On The Driven Roller Assembly/Paper Exit Section Sensor/Mirror For The Sensor - Konica Minolta DF-606 Service Manual

Hide thumbs Also See for DF-606:
Table of Contents

Advertisement

Field Service Ver1.0 Jun.2005
2.4

Maintenance procedure of the paper exit section

2.4.1
Cleaning the mirror on the driven roller assembly/paper exit section sensor/mirror for the
sensor
A. Periodic cleaning cycle
Mirror on the driven roller assembly: Every 500,000 prints
Original reverse sensor (PS309): Every 500,000 prints
Reverse jam sensor (PS304): Every 500,000 prints
Original reverse/exit sensor (PS313): Every 500,000 prints
B. Procedure
[2]
[3]
[2]
[1]
[2]
15saf2c026na
[4]
[1]
15saf2c027na
[1]
15saf2c028na
1. Remove the driven roller assembly. (See "2.3.1
Cleaning the read section sensor/mirror for the
sensor.")
2. Use a blower brush to clean the mirror [2] on the
driven roller assembly [1].
3. Open the DF and then open the platen guide [1].
4. Use a blower brush to clean the original reverse
sensor (PS309) [2], the reverse jam sensor
(PS304) [3] and the original reverse/exit sensor
(PS313) [4].
5. Use a blower brush to clean 2 mirrors [2] provided
on the back side of the platen guide [1].
6. Reinstall the above parts following the removal
steps in reverse.
2. PERIODIC CHECK
17

Advertisement