2. PERIODIC CHECK
[4]
10
[1]
[2] [3]
15ssf2c011na
Field Service Ver2.0 Aug.2005
5. Pull out and remove the separation roller [1] from
the collar [2] and the shaft [3].
Note
• When reinstalling the separation roller, be
sure to insert it into the collar [2] from the
paint-marked [4] side.
• Be sure to check to see if the surface of the
separation roller is not smeared with grease.
6. Reinstall the above parts following the removal
steps in reverse.