Staple Position Adjustment (Flat-Stapling); Position Adjustment For Fs-509 - Konica Minolta DF-606 Service Manual

Hide thumbs Also See for DF-606:
Table of Contents

Advertisement

Field Service Ver2.0 Aug.2005
4.7

Staple position adjustment (flat-stapling)

Conduct this adjustment when the staple position is not within the standard value.
4.7.1

Position adjustment for FS-509

Note
• Be sure not to move the stapler unit in the horizontal direction by hand. Otherwise, it may cause
the belt and gear tooth skipping.
A. Procedure
[1]
1. Conduct the 2-staple mode (flat stapling) and
check to see if the staple position is within the
standard value.
Standard value: A = 10 ± 3mm
(In the flat-stapling, the edge of the paper and the
line connecting 2 staples [1] should be in parallel.)
Conduct the following adjustment when the value
is not within the standard value or when they are
not in parallel.
15sff3c014na
4. MECHANICAL ADJUSTMENT
1