3. OTHERS
[1]
[3]
[2]
14
[2]
15kvf2c012na
[1]
15kvf2c013na
Field Service Ver1.0 Jun.2005
5. Pull out the retaining lever to the front to release
ZU and FS, and then tilt the upper part of ZU [2]
and disconnect 2 connectors [3].
6. Lift up ZU [1] with 2 people and remove it from FS
[2].
Note
• When reinstalling ZU, be sure that the wiring
harness is not caught by the FS and ZU.
7. Reinstall the above parts following the removal
steps in reverse.