3. OTHERS
3.2
Removal procedure of parts to be disassembled and assembled
Caution
• When connected to the main body, be sure to unplug the power cord of the main body from the
power outlet.
3.2.1
Removing and reinstalling the upper door
A. Procedure
[5]
3.2.2
Removing and reinstalling the right cover
A. Procedure
[2]
18
[1]
[2]
[6]
[4]
[3] [5]
15ssf2c024na
[1]
[1]
15ssf2c025na
Field Service Ver2.0 Aug.2005
1. Open the upper door [1].
2. Release the hook [3] of the spring [2] from the
paper feed guide plate [4].
3. Remove 2 screws [5] and slide the upper door [1]
in the arrow-marked [6] direction. Then remove it
upward.
4. Reinstall the above parts following the removal
steps in reverse.
1. Open the upper door.
2. Remove 5 screws [1] and then remove the right
cover [2].
3. Reinstall the above parts following the removal
steps in reverse.