Replacing The Separation Roller /Lw And The Torque Limiter /Lw - Konica Minolta DF-606 Service Manual

Hide thumbs Also See for DF-606:
Table of Contents

Advertisement

2. PERIODIC CHECK
[1]
[1]
[2]
[4]
2.1.4

Replacing the separation roller /Lw and the torque limiter /Lw

A. Periodically replaced parts/cycle
Separation roller /Lw: Every 500,000 prints (every 100,000 prints for actual replacement cycle)
Torque limiter /Lw: Every 3,000,000 prints (every 600,000 prints for actual replacement cycle)
B. Procedure
6
[2]
15jff2c006na
[3]
[5]
15jff2c007na
[1]
[2]
15jff2c008na
Field Service Ver1.0 Jun.2005
3. Release hooks [1] at the both sides, and then lift
up and remove the separation roller unit /Up [2].
4. Remove the C-clip [1] from the separation roller
unit /Up, and then remove the separation roller /
Up [2] and the torque limiter /Up [3].
5. Reinstall the above parts following the removal
steps in reverse.
Note
• Install the separation roller with 2 notches [4]
face to the front and be aligned with the
prong [5].
1. Pull the release lever [1] and open the top door [2].
2. Perform the steps 2, 3, and 4 in "2.1.3 Replacing
the separation roller /Up and the torque limiter /
Up."
3. Reinstall the above parts following the removal
steps in reverse.

Advertisement

Table of Contents
loading

Table of Contents