Cleaning The Paper Feed Section Sensor - Konica Minolta DF-606 Service Manual

Hide thumbs Also See for DF-606:
Table of Contents

Advertisement

Field Service Ver1.0 Jun.2005
2.1.6

Cleaning the paper feed section sensor

A. Periodic cleaning cycle
Original count sensor (PS310): Every 500,000 prints
Original size sensor /Lt (PS303): Every 500,000 prints
Original size sensor /Rt (PS302): Every 500,000 prints
B. Procedure
[1]
[2]
[3]
15saf2c020na
1. Close the DF.
2. Use a blower brush to clean the original count
sensor (PS310) [1], the original size sensor /Lt
(PS303) [2] and the original size sensor /Rt
(PS302) [3].
2. PERIODIC CHECK
13

Advertisement

Table of Contents
loading

Table of Contents