FUEL SYSTEM (PGM-FI)
Remove the torx screws, setting plate and IACV.
Check the IACV for wear or damage.
If necessary, replace the IACV with a new one.
INSTALLATION
Turn the slide valve clockwise until lightly seated on
IACV.
Install the IACV aligning its groove with the IACV
cover pin.
Install the setting plate and tighten the torx screws
to the specified torque.
TORQUE: 2.1 N·m (0.2 kgf·m, 1.5 lbf·ft)
5-80
SETTING PLATE
SETTING PLATE
TORX SCREWS
Align
TORX SCREWS