3. ECM Signal Line Open Circuit Inspection
Disconnect the ECM 33P (Gray) connector.
Disconnect the ABS modulator 26P connector.
Check the continuity between the ECM 33P
(Gray) connector and combination meter 20P
connector (XL700V) or ABS modulator 26P con-
nector (XL700VA).
Connection: B28 – Pink/green
TOOL:
Test probe
Is there continuity?
YES
– Open circuit in Pink/green wire
NO
– Replace the ECM with a new one, and
recheck; for Key Registration Proce-
dures (page 21-4).
XL700V:
07ZAJ-RDJA110
COMBINATION METER 20P CONNECTOR
(Wire side/female terminal)
XL700VA:
FUEL SYSTEM (PGM-FI)
33P (GRAY) CONNECTOR
(Wire side/female terminal)
P/G
33P (GRAY) CONNECTOR
(Wire side/female terminal)
B28
P/G
ABS MODULATOR 26P CONNECTOR
(Wire side/female terminal)
B28
5-29