Yamaha RCX240 User Manual page 244

4-axis robot controller
Hide thumbs Also See for RCX240:
Table of Contents

Advertisement

11. "MANUAL" mode
■ Key operations to move to a position where absolute reset is possible
For instance, when the current axis position is q (machine reference: 82%):
1
Press
50%. (Absolute reset is now possible.)
or
2
Press the
around 50%. (Absolute reset is now possible.)
3
4
■ Absolute reset position and "0" pulse position
5
When absolute reset is performed at position A, the position B (machine reference 38%) is reset
as the "0" pulse position. This means that the robot will move to the "0" pulse position after
performing absolute reset with the servo turned on.
w
WARNING
6
THE ROBOT STARTS TO MOVE WHEN ABSOLUTE RESET IS PERFORMED. TO AVOID
DANGER, DO NOT ENTER THE ROBOT MOVEMENT RANGE.
7
Minus (-) direction
8
9
10
4-166
Chapter 4 OPERATION
(ADJ.+) to move to position w and the machine reference will change to around
(ADJ.-) to move to position e and the machine reference will change to
Key operations to move to a position where absolute reset is possible
Minus (-) direction
0
25
: Range in which absolute reset can be made (44 to 56%).
Absolute reset position and "0" pulse position
0
: Range in which absolute reset can be made (44 to 56%).
e
q
50
75
0
25
B
A
25
50
75
Plus (+) direction
w
50
75
0
Machine reference (%)
Plus (+) direction
0
Machine reference (%)

Advertisement

Table of Contents
loading

Table of Contents