3.3.6 CU-Board

(1) Remove the Cover-Side-R. (Refer to 3.3.4)
(2) Remove the five screws (Silver)
(3) Remove the two screw (Silver : Small)
(4) Disconnect every cord from CU-Board
(5) Installing is performed by the inverse procedure with removing.
(Note on removing / installing)
1. Beware of not to touch the DC motor inattentively (Do not rotate motor).
2. Beware of not to tuck down the cable while installing the Plate-Shield
3. See 7.2(1) for the CU-Board
44983601TH Rev.1
. Remove the Plate-Shield
, remove the two screw (Silver)
and remove the CU-Board
connector layout.
3. Parts replacement
.
.
.
.
3-11 /