Appendix

A.1

Parameter

Parameters are the interface between the firmware of the inverter and the commissioning
tool, e.g. an operator panel.
Adjustable parameters
Adjustable parameters are the "adjusting screws" with which you adapt the inverter to its
particular application. If you change the value of an adjustable parameter, then the inverter
behavior also changes.
Adjustable parameters are shown with a "p" as prefix, e.g. p1082 is the parameter for the
maximum motor speed.
Display parameters
Display parameters allow internal measured quantities of the inverter and the motor to be
read.
Display parameters are shown with a "r" as prefix, e.g. p0027 is the parameter for the
inverter output current.
Commonly used parameters
Table A- 1
Switching to commissioning mode or restore the factory setting
Parameter
Description
p0010
Commissioning parameters
0: Ready (factory setting)
1: Perform quick commissioning
3: Perform motor commissioning
5: Technological applications and units
15: Define number of data records
30: Factory setting - initiate restore factory settings
Table A- 2
How to determine the firmware version of the Control Unit
Parameter
Description
r0018
The firmware version is displayed:
SINAMICS G120C frequency converter
Operating Instructions, 03/2012, FW V4.5, A5E02999804B AB
A
313