6.4.2

Changing settings using BOP-2

Changing settings using BOP-2
With the BOP-2 you change your converter settings by selecting a parameter via its number
(e.g. p0327) and by changing the value of the parameter change.
In the parameters starting with an "r" (for example r0020), the converter will display internal
values. You cannot change the value of an r-parameter.
The converter immediately saves all settings which you made using the BOP-2 so that they
are protected against power failure.
Procedure
Select the parameters
If the parameter number flashes in the display,
you have two options for changing the number:
1. option:
6.4.3

Additional settings

The Section Commissioning guidance (Page 49) shows you what still has to be set after the
basic commissioning in order to adapt the inverter to your application.
SINAMICS G120C frequency converter
Operating Instructions, 03/2012, FW V4.5, A5E02999804B AB
ESC
OK
ESC
OK
2. option:
Increase or
decrease the
parameter number
using the arrow
keys until the
number you want is
displayed.
Confirm the parameter number using the OK
key.
6.4 Basic commissioning with Operator Panel BOP-2
Changing a parameter value
OK
If the parameter value flashes in the display, you
have two options of changing the value:
1. option:
Press and hold the
OK key for more
than two seconds
and change the
required parameter
number digit by
digit.
Basic commissioning
ESC
OK
ESC
OK
2. option:
Increase or
decrease the
parameter value
using the arrow
keys until the value
you want is
displayed.
Confirm the parameter value using the OK
key.
OK
Press and hold the
OK key for more
than two seconds
and enter the
required value digit
by digit.
63