Alarms, faults and system messages
12.1 Operating states indicated on LEDs
Table 12- 5
LED BF display for CANopen
In addition to the signal states "on" and "off" there are three different flashing frequencies:
Table 12- 6
GREEN - single flash Bus state "Stopped"
RED - single flash
RED - double flash
280
Diagnostics of the safety functions
SAFE LED
YELLOW - on
YELLOW - slow
YELLOW - rapid
Communication diagnostics via CANopen
BF LED
Explanation
GREEN - on
Bus state "Operational"
GREEN - fast
Bus state "Pre-Operational"
RED - on
No bus
Alarm - limit reached
Error event in control (Error Control Event)
Meaning
One or more safety functions are enabled, but not active.
One or more safety functions are active; no safety function faults have
occurred.
The converter has detected a safety function fault and initiated a STOP
response.
Operating Instructions, 03/2012, FW V4.5, A5E02999804B AB
SINAMICS G120C frequency converter