Siemens SINAMICS G120 Operating Instructions Manual page 243

Frequency converter
Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

Reduced acceptance
A full acceptance test is necessary only after first commissioning. An acceptance test with a
reduced scope is sufficient when safety functions are expanded.
The acceptance test must be carried out individually for each drive as far as the machine
allows it.
Table 9- 60
Reduced scope acceptance test for function expansions
Measure
Replacing the Control Unit (SINAMICS
G120) or the inverter.
Replacing the Power Module.
Replacing the motor
Replacing the gear unit
Replacing the safety-related peripherals
(e.g. Emergency Stop switch).
Inverter firmware update.
Changing a single limit (e.g. SLS level).
Functional expansion of the machine
(additional drive).
Functional expansion of a drive (e.g.
additional SLS level).
Transfer of inverter parameters to other
identical machines by means of standard
commissioning.
SINAMICS G120C frequency converter
Operating Instructions, 03/2012, FW V4.5, A5E02999804B AB
Acceptance test
Yes
Yes
Yes, but only for the safety
function SDI.
Yes
Yes, but only for the
replaced components.
Yes
Yes, but only for the
changed limit value.
Yes, but only for the
additional functions.
Yes, but only for the
additional functions.
Yes
9.10 Fail-safe function Safe Torque Off (STO)
Acceptance test
Documentation
Supplement inverter data
Log the new checksum
Countersignature
Supplement the hardware version in the inverter
data
No change
No change
No change
Supplement firmware version in the inverter
data
Log the new checksum
Countersignature
Supplement function table
Supplement limit values
Log the new checksum
Countersignature
Supplement machine overview
Supplement inverter data
Supplement function table
Supplement limit values
Log the new checksum
Countersignature
Supplement function table
Supplement limit values
Log the new checksum
Countersignature
Supplement machine description
Check the checksums
Check the firmware versions
Functions
241

Advertisement

Table of Contents
loading