Technical data
13.4 Electromagnetic Compatibility
EMC Immunity
The converter has been tested in accordance with the immunity requirements of category C3
(industrial) environment:
Table 13- 3
EMC Phenomenon
Electrostatic Discharge (ESD)
Radio-frequency
Electromagnetic Field
Amplitude modulated
Fast Transient Bursts
Surge Voltage
1.2/50 μs
Conducted
Radio-frequency Common Mode
Mains Interruptions & Voltage
Dips 400 V
Interruptions & Voltage Dips
24 V
Voltage Distortion
Voltage Unbalance
Frequency Variation
Commutation Notches
1
Note
The immunity requirements apply equally to both filtered and unfiltered units.
300
EMC Immunity
only relevant if 400 V power supply is switched off. The converter reacts to short dips (1 ... 3 ms)
with a fault (F30074, can be acknowledged), but does not interrupt the fieldbus communication.
Standard
Level
EN 61000-4-2
4 kV Contact discharge
8 kV Air discharge
EN 61000-4-3
80 MHz ... 1000 MHz
10 V/m
80 % AM at 1 kHz
EN 61000-4-4
2 kV @ 5 kHz
EN 61000-4-5
1 kV differential (L-L)
2 kV common (L-E)
EN 61000-4-6
0.15 MHz ... 80 MHz
10 V/rms
80 % AM at 1 kHz
EN 61000-4-11
95 % dip for 3 ms
30 % dip for 10 ms
60 % dip for 100 ms
95 % dip for 5000 ms
95 % dip for 3 ms
EN 61000-2-4
10 % THD
EN 61000-2-4
3 % Negative Phase Sequence
EN 61000-2-4
Nominal 50 Hz or 60 Hz (± 4 %) A
EN 60146-1-1
Depth = 40 %
Area = 250 % x degrees
Operating Instructions, 03/2012, FW V4.5, A5E02999804B AB
Performance
Criterion
A
A
A
A
A
A
C
C
D
A
1
A
A
A
SINAMICS G120C frequency converter