11.1.12 Scanner Parameters Lists
11.1.12.1
ASC Parameters Lists
Serial number.
Initial
No.
Value
0
0
Parameters used with USB tool
Initial
No.
Value
1
60
2
4965
Switching parameters when calibrating
Initial
No.
Value
3
0
4
0
5
0
6
0
7
0
8
0
9
0
10
0
Unit
Range
━
━
Input and display the serial number
(ASC/SC board serial)
Unit
Range
━
mm/s
Switch the reading speed
60: 60 mm/s
30: 30 mm/s
━
━
Set the read length
Unit
Range
━
0 to 1
Switch shading
0: On 1: Off
━
0 to 1
Scanning with/without motor/sensor
0: Motor/sensor enabled、
1: Motor/sensor disabled
━
0 to 1
Switch sensor connection processing
0: On 1: Off
━
0 to 1
Switch tone curve
0: Use the specified curve
1: Use the linear curve
━
0 to 1
Switch motor advance
0: Use the specified parameter
1: Use the initial value
━
0 to 1
Switch connection adjustment
0: Use connection adjustment value
1: Use initial value for adjustment
━
0 to 2
Switch light intensity calibration
(for front LED)
0: Use after-calibration parameter
1: Use initial value for calibration
2: Use value = 0
━
0 to 2
Switch light intensity calibration
(for rear LED)
0: Use after-calibration parameter
1: Use initial value for calibration
2: Use value = 0
Chapter 11 Scanner Calibration
Meaning
Meaning
Meaning
Changes
after
Note
Calibration
━
The serial number
is adjusted during
the process.
Changes
after
Note
Calibration
━
━
Changes
after
Note
Calibration
━
━
━
━
━
━
━
━
11-49