Monochrome scan motor control parameters
Initial
No.
Unit
Value
63
8
64
8
65
8
66
8
67
24075
pps
68
6019
pps
69
12037
pps
70
6019
pps
71
6019
pps
72
6019
pps
73
4013
pps
74
6019
pps
75
3009
pps
76
6019
pps
77
100
msec
78
100
msec
79
24075
pps
80
6019
pps
81
12037
pps
Range
Switch motor step mode
Full step: 1
Half step: 2
Micro step (1/8): 8
Micro step (1/16): 16
Switch motor step mode
Full step: 1
Half step: 2
Micro step (1/8): 8
Micro step (1/16): 16
Switch motor step mode
Full step: 1
Half step: 2
Micro step (1/8): 8
Micro step (1/16): 16
Switch motor step mode
Full step: 1
Half step: 2
Micro step (1/8): 8
Micro step (1/16): 16
23075 to
Rotational speed when feeding the original
25075
forward at 240 mm/s
5019 to
Rotational speed when feeding the original
7019
backward at 240 mm/s after scanning
11037 to
Rotational speed when feeding the original
13037
forward at 120 mm/s
5019 to
Rotational speed when feeding the original
7019
backward at 120 mm/s after scanning
5019 to
Rotational speed when feeding the original
7019
forward at 60 mm/s
5019 to
Rotational speed when feeding the original
7019
backward at 60 mm/s after scanning
3013 to
Rotational speed when feeding the original
5013
forward at 40 mm/s
5019 to
Rotational speed when feeding the original
7019
backward at 40 mm/s after scanning
Rotational speed when feeding the original
forward at 30 mm/s
Rotational speed when feeding the original
backward at 30 mm/s after scanning
Excitation time before starting the send
pulse motor (SM01)
Excitation time before stopping the send
pulse motor (SM01)
Initial value for adjustment:
Rotational speed when feeding the original
forward at 240 mm/s
Initial value for adjustment:
Rotational speed when feeding the original
backward at 240 mm/s after scanning
Initial value for adjustment:
Rotational speed when feeding the original
forward at 120 mm/s
Chapter 11 Scanner Calibration
Meaning
Changes
after
Note
Calibration
At 240 mm/s
At 120 mm/s
At 60 mm/s
At 40 mm/s
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
11-53

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lp-1040-mf