11.1.7.2
Sensor Connection Calibration
After the document advance calibration, perform sensor connection calibration in main
scanning and subscanning directions.
This calibration will be performed semi-automatically.
Parameter Details
Main Scanning Direction Sensor Connection Calibration Parameters (for 600 dpi Mode)
Number
ASC-233
ASC-234
ASC-235
ASC-236
ASC-237
ASC-238
ASC-239
ASC-240
ASC-241
ASC-242
Main Scanning Direction Sensor Connection Calibration Parameters (for 300 dpi Mode)
Number
ASC-243
ASC-244
ASC-245
ASC-246
ASC-247
ASC-248
ASC-249
ASC-250
ASC-251
ASC-252
Note:
Specify which range to use to scan for each CIS' 5104 Dot (in 600 dpi mode) or 2552 Dot (in
300 dpi mode) for A through E.
The layout of the CIS is from A to E from the right when you are facing the Printer.
Units
Range
Dot
0 - 5104
Dot
5104 - 10208
Dot
10208 - 15312
Dot
15312 - 20416
Dot
20416 - 22520
Dot
0 - 5104
Dot
5104 - 10208
Dot
10208 - 15312
Dot
15312 - 20416
Dot
20416 - 22520
Units
Range
Dot
0 - 2552
Dot
2552 - 5104
Dot
5104 - 7658
Dot
7658 - 10208
Dot
10208 - 12760
Dot
0 - 2552
Dot
2552 - 5104
Dot
5104 - 7658
Dot
7658 - 10208
Dot
10208 - 12760
Chapter 11 Scanner Calibration
CIS(A) main scanning direction's first dot position
CIS(B) main scanning direction's first dot position
CIS(C) main scanning direction's first dot position
CIS(D) main scanning direction's first dot position
CIS(E) main scanning direction's first dot position
CIS(A) main scanning direction's end dot position
CIS(B) main scanning direction's end dot position
CIS(C) main scanning direction's end dot position
CIS(D) main scanning direction's end dot position
CIS(E) main scanning direction's end dot position
CIS(A) main scanning direction's first dot position
CIS(B) main scanning direction's first dot position
CIS(C) main scanning direction's first dot position
CIS(D) main scanning direction's first dot position
CIS(E) main scanning direction's first dot position
CIS(A) main scanning direction's end dot position
CIS(B) main scanning direction's end dot position
CIS(C) main scanning direction's end dot position
CIS(D) main scanning direction's end dot position
CIS(E) main scanning direction's end dot position
Meaning
Meaning