Table 2-8 Unrecoverable Error Codes And Their Details - Oki LP-1040 Maintenance Manual

Wide format multifunction printer
Hide thumbs Also See for LP-1040:
Table of Contents

Advertisement

(1) Unrecoverable Error Codes and Their Details

Table 2-8 Unrecoverable Error Codes and Their Details

Error Code
2010
2011 - 2013
2014 - 2016
2017 - 2019
201A - 201C
2021 - 2022
2023
2024 - 2026
2027 - 202B
2030
2031
2032
2035
2036
2037
203A
2081
2082
2083
2084
2085
2086
2087
2088
2089
208A
208B
208C
208D
20BF
20C1 - 20C3
20C4
20C5
20C8
20C9
20CA
20D1 - 20D8
2E40
2E50
2E51
2E52
2E53
2E54
FMxx (Paper Feed Pulse Motor x) Trouble
FM01 (Paper Feed Pulse Motor 1) Trouble
FM02 (Paper Feed Pulse Motor 2) Trouble
-
-
HM01 (Heat Roller Pulse Motor) Trouble
PM01 (Process Motor) Trouble
GM01 (Developer Pulse Motor) Trouble
TM01 (Paper Feed Pulse Motor) Trouble
AC Power Supply Problem (Problem With 50Hz/60Hz Judgment Value)
High Voltage Power Supply Problem CC at CH1, DB at CH2, and DC at CH3
High Voltage Power Supply Problem (TR at CH3)
LED Head Correction Data Transmission Error (Timeout error)
LED Head Correction Data Transmission Error (Header error)
LED Head Correction Data Transmission Error (Footer error)
AC Power Supply Problem (Problem with zero value)
TH02 (Overheat Thermistor) has detected overheating in the fuser.
TH01 (Fuser Temperature Control Thermistor) problem. Extremely hot (possible cable
short).
TH01 (Fuser Temperature Control Thermistor) has exceeded the fuser's maximum
allowed temperature.
After beginning the warm-up sequence, the fuser temperature TH01 did not reach the
specified temperature within the specified amount of time.
TH03 (LED Head Temperature Measurement Thermistor) Problem
Extremely hot (possible cable short).
TH03 (LED Head Temperature Measurement Thermistor) has exceeded the LED
head's maximum allowed temperature.
TH04 (Fuser Temperature Control Thermistor) problem. Extremely hot (possible cable
short).
TH04 (Fuser Temperature Control Thermistor) has exceeded the fuser's maximum
allowed temperature.
After beginning the warm-up sequence, the fuser temperature TH04 did not reach the
specified temperature within the specified amount of time.
The temperature difference between TH01 and TH04 is too large.
TH05 (Backup Roller Temperature Measurement Thermistor) Problem
TH06 (Humidity Sensor Unit Temperature Measurement Thermistor) Problem
HU01 (Humidity Sensor) Problem
No folding completion notice from the folder
EEPROM Checksum Error (System parameter)
EEPROM Checksum Error (Print length after part replacement)
EEPROM Checksum Error (Print length after part cleaning)
EEPROM Checksum Error (Unrecoverable error log)
EEPROM Checksum Error (Paper jam error log)
EEPROM Checksum Error (Process cartridge usage log)
EEPROM Checksum Error (Engine Control Parameter)
Actuator Communication
Actuator Communication
Actuator Communication
Actuator Communication
Actuator Communication
Actuator Communication
Chapter 3 Regular Service Inspectionse
Error Details
Initialization is not complete
Output port write error
Packet error
Parity error
Communication timeout
Buffer overflow error
2-11