6.
Remove the plate clamp with two screws on
the left side of the fuser.
7.
Remove all light blue colored cable clamps
and unplug all connectors.
8.
Hold down the halogen heater with a
non-woven fabric cloth and pull out both the
FL01 and FL02 halogen heaters from the
right side of the unit.
Note
 Handle the halogen heaters carefully, as they
are very fragile.
 Remove the cables and connectors carefully,
as they may snag easily on other parts.
9-100
Plate clamp
Fuser left side
Do not tangle the cable.