Position Adjustment Instructions - Oki LP-1040 Maintenance Manual

Wide format multifunction printer
Hide thumbs Also See for LP-1040:
Table of Contents

Advertisement

11.1.8

Position Adjustment Instructions

This calibration is performed separately for monochrome, color, and for each scan speed. The
calibration items are classified into three below:
- Right scan edge adjustment
The adjustment value is consistent regardless of the monochrome or color scan mode
and scan speed.
- Top scan edge adjustment
- Bottom scan edge adjustment
The adjustment value is valid only in the synchronous scan mode.
11.1.8.1
Position Adjustment Parameter Details
Monochrome parameters
Number
ASC-15
ASC-47
ASC-48
ASC-49
ASC-50
ASC-51
ASC-52
ASC-53
ASC-54
Units
Range
1/10mm
14 to 94
msec
-
msec
-
msec
-
msec
-
line
-
line
-
line
-
line
-
Default
Value
Specifies the offset value for the document table and
47
CIS unit.
Specifies the time for the five A4 width CISs to start
scan at 240 mm/s for top scan edge adjustment.
374
The adjustment value is determined based on the
CIS(C), that is, C-position CIS.
Specifies the time for the five A4 width CISs to start
scan at 120 mm/s for top scan edge adjustment.
748
The adjustment value is determined based on the
CIS(C), that is, C-position CIS.
Specifies the time for the five A4 width CISs to start
scan at 60 mm/s for top scan edge adjustment.
1496
The adjustment value is determined based on the
CIS(C), that is, C-position CIS.
Specifies the time for the five A4 width CISs to start
scan at 40 mm/s for top scan edge adjustment.
2244
The adjustment value is determined based on the
CIS(C), that is, C-position CIS.
Specifies the number of lines scanned after the
registration sensor at 240 mm/s in synchronous scan
2081
mode, which is calculated at 600dpi rate.
The adjustment value is determined based on the
CIS(C), that is, C-position CIS.
Specifies the number of lines scanned after the
registration sensor at 120 mm/s in synchronous scan
2081
mode, which is calculated at 600dpi rate.
The adjustment value is determined based on the
CIS(C), that is, C-position CIS.
Specifies the number of lines scanned after the
registration sensor at 60 mm/s in synchronous scan
2081
mode, which is calculated at 600dpi rate.
The adjustment value is determined based on the
CIS(C), that is, C-position CIS.
Specifies the number of lines scanned after the
registration sensor at 40 mm/s in synchronous scan
2081
mode, which is calculated at 600dpi rate.
The adjustment value is determined based on the
CIS(C), that is, C-position CIS.
Chapter 11 Scanner Calibration
Meaning
11-37

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lp-1040-mf

Table of Contents