Fusing Entrance Sensor - Ricoh MP C307 Field Service Manual

Hide thumbs Also See for MP C307:
Table of Contents

Advertisement

Fusing
Make sure that both side plates fit right into the locating bosses of the frame before securing the screws.
The new fusing sleeve belt assembly has a jig [A], which must be removed. Set the fusing sleeve belt assembly
first, tighten the screws, then remove the jig.

Fusing Entrance Sensor

1.
Open the right door.
If you find paper dust in the registration section when you open the right door, remove the dust.
Otherwise, the dust can cause lines on the image.