Avaya CallPilot 201i Maintenance And Diagnostics page 32

Hide thumbs Also See for CallPilot 201i:
Table of Contents

Advertisement

Troubleshooting your Avaya CallPilot® system
Stage
2
3
4
5
6
7
8
9
10
11
32
Avaya CallPilot® 201i Server Maintenance and Diagnostics
Description
This is the start of critical startup diagnostics for
the 8051 system controller. If any of the tests fail,
the startup cycle is halted.
Approximate duration: less than 1 second
ALU self-test
Approximate duration: less than 1 second
Address mode self-test
Approximate duration: less than 1 second
Boot ROM self-test
Approximate duration: less than 1 second
Timer self-test
Approximate duration: less than 1 second
Watchdog self-test
Approximate duration: less than 1 second
EEPROM self-test
This is a noncritical diagnostic. If it fails, this is a
noncritical error, and the start cycle continues.
Approximate duration: less than 1 second
End of system controller self-tests. No errors were
found.
Approximate duration: less than 3 seconds
Beginning of BIOS diagnostics
Note:
The BIOS splash screen appears, and HOST
scrolls across the HEX display.
Approximate duration: 7 seconds
Beginning of the operating system start sequence
The monitor displays the operating system logon
prompt.
You are prompted for an operating system user
name and password. If the system needs to be
configured, a pop-up box for Maintenance
Configuration Detection Information may appear
to remind you.
If the Maintenance Configuration Detection
Information box appears, click OK unless you
want a reminder to configure the server.
Completion of operating system start sequence.
The 8051 system controller is running normally.
HEX
Status LED
display
T:02
ON
T:03
ON
T:04
ON
T:05
ON
T:06
ON
T:07
ON
T:08
blinks three
times
HOST
ON
NT
OFF
OK
OFF
December 2010

Advertisement

Table of Contents