[SKO_Index0]
Example of the "sltlprodiaghmi.ini" with 5 components
[SK0]
ComboCount=5
[SK0_Index0]
DiagType= 1
TypeSection=CP142-2
Logical_Address=43
RequestDB=449
[SK0_Index1]
DiagType= 2
TypeSection=CP343-2
Logical_Address=75
RequestDB=449
[SK0_Index2]
DiagType= 3
TypeSection=DP-AS-i-Link
Logical_Address=75
RequestDB=449
[SK0_Index3]
DiagType= 4
TypeSection=DP-AS-i-Link-20E
Logical_Address=75
RequestDB=449
SINUMERIK Operate (IM9)
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1
DiagType= 6
TypeSection=DP-AS-i-Link-
Advanced 1
Logical_Address=43
RequestDB=449
18.13 PROFIBUS/PROFINET and AS-i bus diagnostics
Description
1. Entry
Type ID of the AS-i component (refer above)
Designation of the AS-i component, which should be
output in the selection list
E address of the AS-i component from the hardware
configuration
Instance DB of the function block "FB_SL_COM" be‐
ing used