Siemens SINUMERIK 840DE sl Commissioning Manual page 294

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840DE sl:
Table of Contents

Advertisement

Configuring alarms
13.3 Configuring an alarm log
Cancel criteria
Cancel criteri‐
on (ClearInfo)
Examples
Log all alarms with a ClearInfo not equal to 15, i.e. no part program messages:
<CONFIGURATION>
<Protocol>
</Protocol>
</CONFIGURATION>
Log all alarms with the SourceURL "/NCK" or "/HMI":
<CONFIGURATION>
<Protocol>
</Protocol>
</CONFIGURATION>
280
Alarm source
(Source)
0
/HMI
1
/NCK
2
3
4
5
6
7
8
/PLC
9
10
11
12
13
14
/NCK
15
16
<Filters>
<Siemens_Filter_01 type="QString" value="CLEARINFO NOT 15" />
</Filters>
<Filters>
<Filter_01 type="QString" value="SourceURL EQUAL /NCK" />
<Filter_02 type="QString" value="SourceURL EQUAL /HMI" />
</Filters>
Description
Alarms that are canceled by the HMI.
Alarms that are canceled by power-on of the NCU.
Conditions are canceled by a hardware reset of the NCU.
Conditions are deleted by a "CANCEL" command to the NCU.
Conditions are canceled by the NCK itself.
Conditions are canceled by an "NC Start" command on the NCU.
Conditions are canceled by a reset of the mode group (BAG).
Conditions are canceled by an "NC Reset" command on the NCU.
PLC messages of the FB15 (basic program).
PLC alarms of the FB15 (basic program).
Dialog alarms of the HMI that are canceled by the "Recall" key [^].
Reserved
S7-PDiag, S7-Graph, S7-HiGraph or other Alarm_S(Q) alarms of
the PLC (SFC17/18) with alarm state "not acknowledged"
S7-PDiag, S7-Graph, S7-HiGraph or other Alarm_S(Q) alarms of
the PLC (SFC17/18) with alarm state "acknowledged".
Drive alarms via NCK.
Part program messages.
SINAMICS Safety Integrated messages
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1