Siemens SINUMERIK 840DE sl Commissioning Manual page 377

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840DE sl:
Table of Contents

Advertisement

Procedure
16.6
Reading in an archive with original data
The data of the original controller state is stored in the "original.arc" file. If you want to restore
the controller to the as-delivered state, you can read in the original data archive.
Precondition
You require access level 2 (service).
Procedure
SINUMERIK Operate (IM9)
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1
1.
Select the "Start-up" operating area.
2.
Press the menu forward key.
3.
Press the "Start-up archive" softkey.
The "Start-up" window opens.
4.
Activate the "Create archive of original status" checkbox and press the
"OK" softkey.
The "Create Start-up for Original Status" window opens.
5.
Select the desired control components.
6.
When required, enter a comment into the field as well as your name and
the date of creation - and then press the "OK" softkey.
A warning is output if an "original.arc" archive file already exists.
7.
Press the "OK" softkey to overwrite the file.
A new archive file is generated and stored in the Archives/Manufacturer
directory.
- OR -
Press the "Cancel" softkey so that the existing file is not overwritten.
1.
Select the "Start-up" operating area.
2.
Press the menu forward key.
16.6 Reading in an archive with original data