SD54675 $SNS_MEA_CM_FEEDFACTOR_1[0]
= 10
= 0
= ≥1
SD54676 $SNS_MEA_CM_FEEDFACTOR_2[0]
= 0
= ≥1
Note
Feedrate factor 2 should be less than feedrate factor 1.
SD54677 $SNS_MEA_CM_MEASURING_ACCURACY[0]
= 0.005
Measurement with rotating spindle: Measured value correction using correction tables
SD54691 $SNS_MEA_T_PROBE_OFFSET
= 0
= 1
= 2
SD54689 $SNS_MEA_T_PROBE_MANUFACTURER
= 0
= 1
= 2
SINUMERIK Operate (IM9)
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1
Default value
Only single probing with the feedrate calculated by the cycle. However, as a minimum, the
value from SD54673[0] $SNS_MEA_CM_MIN_FEEDRATE.
First probing with feedrate. However, as a minimum with the value from
SD54673[0] $SNS_MEA_CM_MIN_FEEDRATE)
SD54675[0] $SNS_MEA_CM_FEEDFACTOR_1
Second probing with the feedrate calculated by the cycle. This is only effective for
SD54673 $SNS_MEA_CM_FEEDFACTOR_1[0] > 0, default value.
Second probing with the calculated feedrate from SD54673 $SNS_MEA_CM_MIN_FEE‐
DRATE[0] feedrate factor 2.
Third probing with the calculated feedrate.
Default value
No data, default value
Correction in the cycle. This is only effective if SD54690 $SNS_MEA_T_PROBE_MANUFAC‐
TURER>0.
Correction using user-defined correction table
No data, default value
TT130 (Heidenhain)
TS27R (Renishaw)
21.10 Measuring cycles and measurement functions
Feedrate factor 1
Feedrate factor 2
Specified measuring accuracy.
The value of this parameter always
refers to the last probing of the tool
at the probe.
Activates the measuring result cor‐
rection
Activate pre-configured compensation
tables for several tool probe models
(customer-specific).