The key behavior is set using the following display machine data.
Setting
MD9009 $MM_KEYBOARD_STATE
= 0
= 2
If the machine data is changed, the system must be rebooted.
3.6
Activating/deactivating the virtual keyboard
The virtual keyboard is configured in the file "slguiconfig.ini".
Procedure
1. Copy the "slguiconfig.ini" file from the folder
/siemens/sinumerik/hmi/template/cfg.
2. Paste the copy of the file into the following directory:
/oem/sinumerik/hmi/cfg or /user/sinumerik/hmi/cfg.
3. Open the file in the editor.
4. To activate or deactivate the keyboard, make the following settings:
– Activating the virtual keyboard:
– Deactivating the virtual keyboard:
5. Double click in the input field to display the keyboard.
3.7
Defining the access rights for the "HMI restart" softkey
Displaying the machine data
Using the following display machine data, set the access rights from which access level the
"HMI restart" softkey is displayed.
For SINUMERIK Operate on PC or PCU, the "EXIT" softkey is displayed.
MD9110_$MM_ACCESS_HMI_EXIT
= 1
SINUMERIK Operate (IM9)
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1
CAPSLOCK off (default value)
CAPSLOCK on
In the section [TouchPanel], EnableTouch = true
In the section [Keyboard], EnableVirtualKeyBoard = true
In the section [TouchPanel], EnableTouch = true
In the section [Keyboard], EnableVirtualKeyBoard = false
Access level 1 (manufacturer), default value
3.7 Defining the access rights for the "HMI restart" softkey
Access level of the "EXIT" softkey