Siemens SINUMERIK 840DE sl Commissioning Manual page 136

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840DE sl:
Table of Contents

Advertisement

Customizing the "Machine" operating area
8.5 Deactivating program test
3 =
4 =
5 =
6 =
7 =
8 =
9 =
10 = condwait.png
11 = condwait.png
12 = condstop.png
...
[CondDelayTime]
DefaultDelayTime=1000
1 = 0
2 = 0
3 = 0
4 = 0
5 = 0
6 = 0
7 = 0
8 = 0
9 = 0
10 = 0
12 = 0
...
8.5
Deactivating program test
There are several program test options to test and run-in a part program that are executed
using the "Program Test" function.
This function is active as standard. You can select the program test with the "PRT" check box
in the "Program control" window in the "Machine" operating area.
Deactivating the program test
You can deactivate the program test using the following configuration machine data. "PRT" is
no longer displayed in the status line.
MD51039 $MNS_PROGRAM_CONTROL_MODE_MASK
Bit 0 = 0
122
condstop.png
; Emergency stop active
condstop.png
; Alarm with stop active
condstop.png
; M0/M1 active
condstop.png
; Block in SBL mode terminated
condstop.png
; NC stop active
condstop.png
; Read-in enable missing
condstop.png
; Feed enable missing
; Dwell time active
; Aux. function acknowledgment missing
; Axis enable missing
; No NC ready
; No mode group ready
; Emergency stop active
; Alarm with stop active
; M0/M1 active
; Block in SBL mode terminated
; NC stop active
; Read-in enable missing
; Feed enable missing
; Dwell time active
; Axis enable missing
Function program test not available
Options for machine - program
control
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1