D2: Frequency Upper/Lower Limits; D3: Jump Frequency - YASKAWA A1000 Technical Manual

Hide thumbs Also See for A1000:
Table of Contents

Advertisement

B.4 d: References
No.
(Addr.
Name
Hex)
d1-14
(28F)
Frequency Reference 14
d1-15
(290)
Frequency Reference 15
d1-16
(291)
Frequency Reference 16
d1-17
(292)
Jog Frequency Reference
<1> Range upper limit is determined by parameters d2-01, Frequency Reference Upper Limit, and E1-04, Maximum Output Frequency.
<2> The setting range is 0.0 to 66.0 in AOLV/PM.
u

d2: Frequency Upper/Lower Limits

No.
(Addr.
Name
Hex.)
d2-01
Frequency Reference Upper
(289)
Limit
d2-02
Frequency Reference Lower
(28A)
Limit
d2-03
Master Speed Reference
(293)
Lower Limit
u

d3: Jump Frequency

No.
(Addr.
Name
Hex)
d3-01
Jump Frequency 1
(294)
d3-02
Jump Frequency 2
(295)
d3-03
Jump Frequency 3
(296)
d3-04
Jump Frequency Width
(297)
<1> Default setting is determined by parameter A1-02, Control Mode Setting.
190
Sets the frequency reference for the drive. Setting units are determined by
parameter o1-03.
Sets the frequency reference for the drive. Setting units are determined by
parameter o1-03.
Sets the frequency reference for the drive. Setting units are determined by
parameter o1-03.
Sets the Jog frequency reference. Setting units are determined by parameter
o1-03.
Sets the frequency reference upper limit as a percentage of the maximum
output frequency.
Sets the frequency reference lower limit as a percentage of the maximum
output frequency.
Sets the lower limit for frequency references from analog inputs as a
percentage of the maximum output frequency.
Eliminates problems with resonant vibration of the motor/machine by
avoiding continuous operation in predefined frequency ranges. The drive
accelerates and decelerates the motor through the prohibited frequency ranges.
Setting 0.0 disables this function.
Parameters must be set so that d3-01 ≥ d3-02 ≥ d3-03.
Eliminates problems with resonant vibration of the motor/machine by
avoiding continuous operation in predefined frequency ranges. The drive
accelerates and decelerates the motor through the prohibited frequency ranges.
Setting 0.0 disables this function.
Parameters must be set so that d3-01 ≥ d3-02 ≥ d3-03.
Eliminates problems with resonant vibration of the motor/machine by
avoiding continuous operation in predefined frequency ranges. The drive
accelerates and decelerates the motor through the prohibited frequency ranges.
Setting 0.0 disables this function.
Parameters must be set so that d3-01 ≥ d3-02 ≥ d3-03.
Sets the dead-band width around each selected prohibited frequency reference
point.
YASKAWA ELECTRIC TOEP C710616 41B YASKAWA AC Drive - A1000 Quick Start Guide
Description
Description
Description
Values
Page
Default: 0.00 Hz
Min.: 0.00
97
<1>
Max.: 400.00
<2>
Default: 0.00 Hz
Min.: 0.00
97
<1>
Max.: 400.00
<2>
Default: 0.00 Hz
Min.: 0.00
97
<1>
Max.: 400.00
<2>
Default: 6.00 Hz
Min.: 0.00
97
<1>
Max.: 400.00
<2>
Setting
Page
Default: 100.0%
Min.: 0.0
Max.: 110.0
Default: 0.0%
Min.: 0.0
Max.: 110.0
Default: 0.0%
Min.: 0.0
Max.: 110.0
Values
Page
Default: 0.0 Hz
Min.: 0.0
Max.: 400.0
Default: 0.0 Hz
Min.: 0.0
Max.: 400.0
Default: 0.0 Hz
Min.: 0.0
Max.: 400.0
<1>
Default:
Min.: 0.0
Max.: 20.0

Hide quick links: