OF 7 Fuser Heat Rod On at
Power Up
Introduction
The Fuser Heat Rod remains on in Power
Up
Mode. This could also happen after
replacing the Overheat Thermostat.
Procedure
The Fuser Heat Rod
is
on during the Power
Up Mode
Y
N
I
Go to the
F-
Fuser RAP.
Switch off the copier and disconnect the
power cord. Disconnect the orange wire
from the Fuser Triac (gate wire). Connect the
power cord and switch on the copier.
The Heat Rod
is
off
Y
N
I
Ensure that the Traic is wired correctly. If
correct, replace the Traic (PL 1 .I).
Switch off the copier and disconnect the
power cord. Connect the orange wire on the
Triac. Disconnect PIJ 9 from the Control
PWB. Connect the power cord and switch on
the copier.
The Heat Rod
is off
Y
N
A B
A
B
Ensure that the Triac is wired correctly.
If
correct, replace the LVPS (PL 1.2).
Ensure that the Triac is wired correctly. If
correct, replace the Control PWB (PL 1.2).
8/96
251 012515
2-83