36. Connect the main power, and enter the
'
diagnostic mode.
37. Configure the copier for the input power t o
be used.
a.
Select diagnostic test 9
b. Press the Copy Contrast UP or
DOWN
button to select
the
number
that corresponds t o the power to be
used:
1
=
120VAC160Hz
2
=
220 VAC, 50 Hz
3
=
230 VAC, 50 Hz
4
=
240 VAC, 50 Hz
c.
Press Start.
38. (251
5
only) Adjust Time Out to Power Saver
mode t o 1 minute.
a. Select diagnostic test 1.
b. Press the Copy Contrast UP or
DOWN button t o select the number
1.
c, Pross
Stort
,
39. (2510 W/Tag 252;2515) Perform the
initialization o l the fuser roll procedure.
(Pages 6-8 t o 6- 1 1).
NOTE:
If
a
"I"
code
is
displayed at this
point in the installation, refer to the
De-Toning procedure on page 6-5
o f this section.
40. Perform the electrostatic series
(2510: ADJ 9.2; 251 5;ADJ 9.3).
41. Switch off the power and remove the
electrometer probe.
NOTE: Place the dusting pouch from the
lnstalla tion Kit inside the right end
cover before installing the cover.
42. (Figure
28):
Install covers and the user guide
pocket.
INSTALL THE USER
B
GUIDE POCKET
Figure
28.
Installing the Document Return
Guide and
the
User Guide Pocket
43. (Figure 29): Switch on the copier
B
PRESS THE Start
BUTTON
. .
SWITCH ON THE
POWER
MAKE A RECORD OF
THE COPY COUNT
METER
Figure
29.
Switching on the Copier
44. Make five copies of test pattern 82E5020
45,
Refer to the test pattern specifications
section and check the copy quality.
NOTE:
If
the copies have an Offsetting copy
quality defect, perform the Oiler
Wick Priming procedure located i n
Section
6.
46. Check that the copy count meter
advanced
Installation