REP 10.7 Stripper Fingers
Parts List on PL 10.4 (2510 W/ Tag 16),
10.5 (251 5). 10.6 (XLB)
Removal
WARNING:
DISCONNECT THE POWER CORD.
WARNING
The Fuser Roll may be hot. Be careful not
t o touch any heated components.
WARNING
Fuser oil can cause revere eye irritation.
Wear protective gloves when handling
parts with fuser oil on them.
Do not
allow the fuser oil to contact your eyes.
Wash your
hands after handling the
components covered with fuser oil.
2.
Remove the oil dispense assembly (REP
10.4, 10.5).
WARNING
The stripper fingers are very sharp; use
care when handling them.
3. (Figure 1) Position the oil dispense
assembly with a support on each end as
shown.
CAUTION
The oil dispense assembly shown in
Figure I i s the new ODUS assembly.
But, this procedure will work with
any other previous oil dispense
assembly.
RIPPER FINGERS
(9)
I
OIL DISPENSE ASSEMBLY
4.
Remove the stripper fingers.
Figure 1. Removing the Stripper Fingers
(Continued)
REP 10.7